HWgroup Water Leak Detection-Location cable L
For more info refer to the “order model specs” tab below
The WLD-Location cable L detects flooding and determines the distance to the point where liquid is detected. When flooding occurs inside buildings or data centers, every second counts. Locating the flooding point makes it possible to quickly identify the exact location, even beneath floors or in inaccessible areas. The WLD-Location cable indicates the location of water, glycol, or other conductive liquid leaks.
The WLD-Location cable L is a sensing cable for detecting water and conductive liquids that also identifies where along the cable the leak occurred. Unlike standard WLD Type A and Type B sensing cables, which only report the presence of liquid somewhere within the entire zone, Type L also locates the position of the leak. Use it where detecting a leak is not enough and its exact location must also be identified. The maximum length of one WLD-L zone is 100 m.
Available WLD location cable lengths:
- WLD-Location cable L, 10m
- WLD-Location cable L, 50m
Typical Applications
- Data centers and server rooms – detection and location of water leaks beneath raised floors, above suspended ceilings, and along service routes.
- Direct Liquid Cooling (DLC) – location of water and conductive coolant leaks around coolant distribution units (CDUs), direct-to-chip systems, manifolds, and liquid-cooling distribution lines.
- Glycol cooling circuits – detection of leaks involving water mixtures with propylene glycol or ethylene glycol used in HVAC and industrial cooling.
- Heating, ventilation, and air conditioning (HVAC) – monitoring leaks from air-conditioning units, chillers, fan-coil units, and condensate drain pipes.
- Piping routes – a location sensing cable installed along piping not only detects a leak but also identifies its position along the cable route.
- Plant rooms and boiler rooms – detection of leaks from boilers, pumps, valves, heat exchangers, and water tanks.
- Commercial and office buildings – protection of rooms, floors, and technical areas using a location cable installed along walls, floors, or critical routes.
- Hotels – monitoring bathrooms, corridors, and service areas where even a small water leak can cause damage across multiple floors.
- Hospitals and laboratories – location of water leaks in areas containing sensitive technology, laboratory equipment, or critical infrastructure.
- Warehouses, archives, and storage facilities – early detection and location of water ingress before goods, documents, or stored materials are damaged.
- Basements and service floors – detection of flooding, seepage, and groundwater ingress along long monitored routes.
- Industrial facilities – monitoring pipelines, tanks, process lines, and production equipment while identifying the location of a liquid leak.
Additional information
| Weight | N/A |
|---|---|
| Order Model | WLD-Location cable L 5+10m, WLD-Location cable L 5+50m, WLD-Location cable L 10m, WLD-Location cable L 50m, WLD-Connecting cable L 5m |
Specifications
Order model specs
Order model specs:
- Two-cable set: WLD Location Cable L, 10 m, and WLD Connecting Cable L, 5 m. Total length: 15 m. Connects to the device’s 4-pin WLD-L zone input (green terminal block).
- Two-cable set: WLD Location Cable L, 50 m, and WLD Connecting Cable L, 5 m. Total length: 15 m. Connects to the device’s 4-pin WLD-L zone input (green terminal block).
- WLD Location Cable 10 m (Type L). Yellow liquid leak location and detection sensing cable. Detects conductive liquids at any point along its entire length and reports the distance to the detected leak. Features a 4-pin connector for connection to a WLD-L
- WLD Location Cable 50 m (Type L). Yellow liquid leak location and detection sensing cable. Detects conductive liquids at any point along its entire length and reports the distance to the detected leak. Features a 4-pin connector for connection to a WLD-L
- WLD-L (4-pin) Connecting Cable, 5 m. Connecting cable for the WLD Location Cable Type L. Includes a terminator. Connects the device’s WLD-L zone input (4-pin green terminal block) to the white 4-pin connector of the WLD Location Cable.